Aluminium structures and technical fabric calculated for the wind and snow of your specific location.

850

g/m² fabric

6061/T6

anodised aluminium

+20

years lifespan

1-6

courts per cover

Structural calculation

Four levels of calculation, and we tell you what each one covers

The same roof can be calculated under different normative frameworks, and that determines the load it withstands and what it requires from you as the owner. We publish all four, with the standard applied in each case.

01

Catalogue configuration

Signed calculation report · CE marking UNE-EN 1090

The standard manufacturing configuration, with frames at 5 m centres. Supplied with construction, setting-out and base reaction drawings, a signed calculation report and CE marking of the structural assembly.

Main profile
250 × 120 × 4
Frame spacing
5.00 m
Loads
Per site

Loads for each project are calculated for its own site before the order is confirmed.

02

Temporary, snow up to 20 kg/sqm

UNE-EN 13782 · EN 1999-1-1

Temporary structure. The standard allows this snow value only where accumulation on the roof is prevented.

Main profile
300 × 120 × 5
Knee braces
SHS 80 × 6.3
Basic wind speed
28 m/s (EN 13782)
Design snow
0.20 kN/sqm

Requires a snow management plan run by the club, with heating equipment or removal before snow builds up.

03

Temporary, snow up to 75 kg/sqm

UNE-EN 13782 · EN 1991-1-3 annex D

Temporary structure with the actual site snow recalculated for a 10-year design life, in accordance with annex D of the Eurocode.

Main profile
400 × 120 × 6
Knee braces
SHS 90 × 8
Basic wind speed
28 m/s (EN 13782)
Design snow
0.75 kN/sqm

04

Permanent, snow up to 90 kg/sqm

Eurocodes EN 1990 · 1991-1-3 · 1991-1-4 · 1999-1-1

Permanent structure calculated with the full Eurocode wind procedure, not with raw dynamic pressure. It covers any site within the published limits, with no conditions of use.

Main profile
400 × 120 × 6
Basic wind speed
29 m/s, terrain II
Peak pressure
1.00 and 1.15 kN/sqm
Design snow
0.90 kN/sqm (T = 50 years)

Where this calculation stops being valid

The design justified by our engineer does not apply if any of these three conditions occurs. In that case we recalculate for the site before confirming the order.

  • Basic wind speed above 29 m/s (104 km/h) in the region of the installation.
  • Coastal area exposed to open sea, lake shore, or flat terrain with no vegetation or nearby obstacles.
  • Snow load above 90 kg/sqm according to the national annex of the Eurocode.

Calculation report signed by an engineer, with explicit assumptions: basic wind speed, terrain category, pressure coefficients and load combinations. Supplied with every project.

What is included

You are not buying a fabric roof: you are buying a project

Six deliverables that ship with every cover and that a marquee fitter does not produce.

Engineering study

A full structural analysis done for your project and your site, not a generic calculation.

Real 3D design

Realistic modelling of your cover, so you see the final structure before anything is built.

AutoCAD drawings

Detailed drawings ready for construction, installation and approvals.

Installation guide

Step-by-step documentation, in case you prefer to install it with your own team.

International certifications

Design and documentation compliant with Eurocode and with UK and USA standards.

Footings

Reinforced concrete isolated footings, typical dimension 1.2 × 1.2 × 0.5 m, subject to soil conditions.

Configurations

How it looks in your case

Choose the number of courts and see real installations of that size.

Covers 1 court
Covers 1 court
Covers 1 court
Covers 1 court
Covers 2 courts
Covers 2 courts
Covers 2 courts
Covers 2 courts
Covers 3 courts
Covers 3 courts
Covers 3 courts
Covers 3 courts
Covers 4 courts
Covers 4 courts
Covers 4 courts
Covers 4 courts
Covers 6 courts
Covers 6 courts

Bespoke cover: any number of courts and any geometry. Tell us the space and we will calculate it.

The component

Structure in detail

Aluminium profile, arch beam and three-dimensional assembly. What sits inside the cover, before the fabric hides it.

250 × 120 mm aluminium alloy column profile
250 × 120 mm aluminium alloy column profile
Arch beam: delivers the 23,200 mm span with no intermediate supports
Arch beam: delivers the 23,200 mm span with no intermediate supports
Full assembly: frames, purlins and bracing
Full assembly: frames, purlins and bracing
Two-court configuration, isometric view
Two-court configuration, isometric view

Accessories

Every cover is fitted to the club

The base cover is combined with whatever the facility calls for.

Side enclosures

Side enclosures

PVC fabric on the sides, for full wind and rain protection.

Fronts and accesses

Fronts and accesses

Doors, windows and front panels, with or without enclosure.

Interior lighting

Interior lighting

Asymmetric LED built into the structure, with even spread across the court.

Natural ventilation

Natural ventilation

Motorised upper windows to move air in warm climates.

Your branding

Your branding

Club logo, sponsors and corporate colours on fabric and structure.

Gutters and drainage

Gutters and drainage

Rainwater collection and drainage integrated into the structure.

Materials

What lasts twenty years

Hard-pressed extruded 6061/T6 aluminium, anodised to prevent oxidation and corrosion. And double PVC-coated polyester fabric at 850 g/m², block-out, waterproof and UV resistant. Every cover is calculated for the wind and snow of your location, not with a generic calculation.

  • Fire retardant certified to DIN 4102 B1
  • From −40 °C to +70 °C
  • Sides that open fully for ventilation
  • Prevents condensation on the glass
See the manufacturing process
What lasts twenty years

Technical data

Cover materials and manufacturing

What the ARC-TOP covers are made of, component by component. The same data as in the technical dossier.

ARC-TOP 23.2 × 25 dimensions

5
Overall width
23,200 mm clear span, with no intermediate internal supports.
Length
25,000 mm in five 5,000 mm bays.
Ridge height
6,500 mm above finished slab level.
Clear height under fabric
3,050 mm around the perimeter.
Covers
Two 20 × 10 m courts side by side, with a perimeter service walkway.

Aluminium structure

3
Main profiles
Aluminium alloy, 250 × 120 mm and 150 × 120 mm sections.
Secondary profiles
100 × 85 × 2.3 mm and 60 × 60 × 2 mm.
Behaviour
Lightweight and corrosion-resistant, with no paint maintenance.

Steel components

3
Elements
Structural beams, diagonal bracing and seamless tube.
Plates
Steel plates from 6 to 20 mm thick.
Protection
Hot-dip galvanised finish on every steel component.

Covering

3
Material
Technical PVC fabric with triangular roof panels and modular fit.
Weight
650 g/m² on roof and sides, up to 850 g/m² depending on configuration.
Resistance
Built for wind, rain, snow and UV exposure all year round.

Cable system

3
Cable
Galvanised steel 6 × 37, 14 mm diameter.
Fixing
Locking clamps and flange connections.
Roof
Reinforced roof structure.

Manufacturing

4
Cutting and drilling
CNC cutting and drilling.
Tolerance
± 0.20 mm.
Edge finish
Slot milling and edge rounding, 5 mm radius.
Control
Welding, finishing and dimensional inspection piece by piece.

Anchoring and foundation

5
Concrete
C30 concrete footing over a 150 mm compacted crushed stone base.
Base plate
10 mm steel plate with six M20 bolts.
Bolts
M20 × 250 mm, grade 8.8, with 60 × 6 washer and 22 mm hole.
Starter bars
Two M14 threaded rebars cast into the concrete.
On existing slab
Can be anchored to existing concrete with plate and chemical anchors, subject to check.

Before deciding

Common questions

The questions that come up in every roofing project. If yours is not here, write to us.

PadelMagic ARC-TOP cover over a bank of courts
How much does it cost to cover a padel court?

It depends on the type of enclosure (roof only, sliding walls or fixed walls), the number of courts and the wind and snow loads of your area, which drive the structural calculation. Since each cover is sized for its location, the price comes from the engineering study — which is included. Tell us about your project and we'll give you a firm figure.

What types of cover do you make?

Three: enclosed with fixed walls and a hinged door, enclosed with sliding walls (which open in summer), and roof only without sides. All modular and made to fit the court.

Does it withstand wind and snow?

Yes, and not in a generic way: it is calculated for your site. The design follows Eurocodes EN 1990, 1991, 1993 and 15088 and the Spanish CTE DB-SE, with real wind and snow load assumptions for the area.

What is the structure made of?

Anodised 6061/T6 aluminium, considerably stronger than ordinary aluminium and with a service life of over 20 years with minimal maintenance. The fabric is 850 g/m² PVC, fire-retardant certified to DIN 4102-B1.

Can you play in summer without overheating?

That's what the sliding walls are for: they open fully and the court ventilates. And the fabric blocks direct light, so heat doesn't build up inside like in an ordinary tent. It also prevents condensation on the glass and keeps the turf dry.

What do I get with the order?

A complete solution: engineering study, real 3D render, AutoCAD plans, installation guide and international certification (Eurocode, UK and USA). All before manufacturing.

What foundations are needed?

Isolated reinforced-concrete footings, on the order of 1.2 × 1.2 × 0.5 m depending on the ground, with pillars anchored by bolts. The exact dimensions come from the structural study of your project.

Do you install it?

We can, or we'll send you the step-by-step installation guide if you prefer to assemble it with your team. The AutoCAD plans come ready for construction and for applying for permits.

A quote for your cover

Tell us how many courts and where. The quote comes with the structural study and the 3D render.

Request a quote